American Standard Furnace Code E3.2
Soft lockout
The pressure switch will not close, so the control cannot prove the draft inducer is moving flue gas and will not open the gas valve.
Manual wording: “Open Pressure Switch”
Documented for: A951X condensing and A801X induced draft furnaces with the seven-segment IFC display
Likely causes, most common first
- Open pressure switch
- Blocked or restricted vent or combustion air piping
- Condensate backing up in the drain or trap (condensing models)
- Draft inducer not running or running weak
- Pressure switch tubing disconnected or plugged
What you can safely check yourself
- Look for blockage - snow, ice, weeds, grass, leaves, or a nest in the furnace venting outside
- On the A951X and other 95% condensing models, check the condensate drain line and trap for a clog and check that any condensate pump is working
- Make sure the furnace door is on properly
When to call a technician
If the venting and drain are clear, the pressure switch, its tubing, or the inducer needs a technician. Do not jumper the pressure switch.
A American Standard furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installer's Guide - Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, Single Stage Condensing Furnaces with High Efficiency Motor (88-A951X001-1D-EN) (American Standard Heating and Air Conditioning, A951X040BU3SAB through A951X120DD5SAB single-stage 95% condensing furnaces (Silver 95 family)) · checked 2026-08-25