HVAC Code Lookup

American Standard Furnace Code E12

Hard lockout

The fuse on the integrated furnace control has opened, so 24 volt control power is lost.

Manual wording: “Open fuse

Documented for: A951X condensing and A801X induced draft furnaces with the seven-segment IFC display

Likely causes, most common first

  1. Open fuse
  2. Short in the low-voltage thermostat or accessory wiring
  3. Short in a control circuit component

What you can safely check yourself

  • Note whether the code appeared right after a thermostat was replaced or new low-voltage wiring was run, and mention that to the technician

When to call a technician

Call a technician. The fuse blew because something shorted; replacing it without finding the short will just blow it again.

A American Standard furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other American Standard codes