American Standard Furnace Code E09
Soft lockout
The inducer limit switch or the condensate pressure switch is open. On a condensing furnace this most often means condensate is backing up.
Manual wording: “Open Inducer Limit Switch or Condensate Pressure Switch”
Documented for: A951X single-stage condensing furnaces
Likely causes, most common first
- Open inducer limit switch or condensate pressure switch
- Blocked condensate drain, trap, or hose
- Frozen condensate in a drain line running through a cold space
- Full or failed condensate pump
- Inducer overheating
What you can safely check yourself
- Check the condensate drain line and trap for a clog
- Check that any condensate pump is plugged in, not full, and pumping
- In freezing weather, check whether any part of the drain line runs somewhere cold enough to freeze
When to call a technician
If the drain and pump are clear, the inducer limit or condensate switch needs a technician. Do not bypass either switch.
A American Standard furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installer's Guide - Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, Single Stage Condensing Furnaces with High Efficiency Motor (88-A951X001-1D-EN) (American Standard Heating and Air Conditioning, A951X040BU3SAB through A951X120DD5SAB single-stage 95% condensing furnaces (Silver 95 family)) · checked 2026-08-25