American Standard Furnace Code E08

Warning

The flame current the control reads is low but still high enough to keep running. This is an early warning, not a shutdown.

Manual wording: “Flame current is low, but still strong enough to allow operation

Documented for: A951X condensing and A801X induced draft furnaces with the seven-segment IFC display

Likely causes, most common first

  1. Flame current is low, but still strong enough to allow operation
  2. Dirty or degraded flame sensor
  3. Weak or poorly positioned burner flame
  4. Marginal grounding

What you can safely check yourself

  • Note that the furnace is likely still heating; schedule service rather than treating it as an emergency

When to call a technician

Schedule service before it turns into an ignition lockout. Cleaning or repositioning a flame sensor means opening the burner compartment, which is a technician's job.

A American Standard furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.