American Standard Furnace 8 Flashes
WarningShown as: 8 flashes, pause, repeat
Low flame sense signal. The furnace is running but the flame current the control reads is weak.
Manual wording: “8 Flashes --- Low flame sense signal”
Documented for: *UD1 / *DD1 and CUB1 / CDB1 fan-assisted gas furnaces with the LED-only integrated furnace control
Likely causes, most common first
- Low flame sense signal
What you can safely check yourself
- Note whether the furnace is still heating; this code usually appears while it is still running
When to call a technician
Schedule service. A weak flame signal usually means the flame sensor needs cleaning or the burner flame is not right, and if it drops further the furnace will lock out. Cleaning a flame sensor means working in the burner compartment, so leave it to a technician.
A American Standard furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installer's Guide - Upflow/Horizontal, Downflow/Horizontal Gas-Fired Furnaces, "Fan Assisted Combustion System" (18-CD19D7-17) (American Standard Heating and Air Conditioning, *UD1A/*UD1B/*UD1C/*UD1D upflow and *DD1B/*DD1C/*DD1D downflow 80% fan-assisted gas furnaces) · checked 2026-08-25
- Installation, Operation, and Maintenance Guide - Upflow Only and Downflow/Horizontal Gas-Fired Furnaces "Fan Assisted Combustion System" (Pub. No. 41-5010-20) (American Standard Heating and Air Conditioning, CUB1A/CUB1B/CUB1C/CUB1D upflow and CDB1A/CDB1B downflow 80% gas furnaces) · checked 2026-08-25