American Standard Furnace: 4 Flashes
Code 4 Flashes: Open temperature limit circuit
Soft lockoutShown as: 4 flashes, pause, repeat
Open temperature limit circuit. A temperature limit switch has opened because the furnace got too hot, which closes the gas valve and stops the burners.
Manual wording: “4 Flashes --- Open Temperature Limit Circuit”
Documented for: *UD1 / *DD1 and CUB1 / CDB1 fan-assisted gas furnaces with the LED-only integrated furnace control
Likely causes, most common first
- Open temperature limit circuit
- Restricted airflow across the heat exchanger - the manual's own limit checkout deliberately trips the limit by restricting the airflow at the return
- Flame roll-out device tripped: all models have a thermal control device on the burner cover and 'in case of flame roll-out, the device will cause the circuit to open which shuts off all flow of gas'
What you can safely check yourself
- Change your filter - a dirty filter can cause your furnace to stop working
- Check that supply registers and return grilles are open and unblocked
- Make sure the furnace door is on properly after changing the filter, as this can prevent the furnace from starting
- Look for snow, ice, weeds, or grass blocking the furnace venting
When to call a technician
If the code returns after a clean filter and open vents, call a technician. A tripped flame roll-out device in particular means combustion gas escaped the burner box and must be diagnosed before the furnace is run again. Never reset or bypass a limit or roll-out switch yourself.
A American Standard furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installer's Guide - Upflow/Horizontal, Downflow/Horizontal Gas-Fired Furnaces, "Fan Assisted Combustion System" (18-CD19D7-17) (American Standard Heating and Air Conditioning, *UD1A/*UD1B/*UD1C/*UD1D upflow and *DD1B/*DD1C/*DD1D downflow 80% fan-assisted gas furnaces) · checked 2026-08-25
- Installation, Operation, and Maintenance Guide - Upflow Only and Downflow/Horizontal Gas-Fired Furnaces "Fan Assisted Combustion System" (Pub. No. 41-5010-20) (American Standard Heating and Air Conditioning, CUB1A/CUB1B/CUB1C/CUB1D upflow and CDB1A/CDB1B downflow 80% gas furnaces) · checked 2026-08-25
- Furnace Troubleshooting - American Standard owner support (American Standard Heating and Air Conditioning, American Standard residential gas furnaces (general)) · checked 2026-08-25