Amana Furnace Code NONE

Hard lockout

The display shows 'nonE' or nothing at all - the control has no power, or the board is dead.

Manual wording: “No 120VAC power to furnace or no 24 volt power to integrated control module.

Documented for: Amana AMVC96, ACVC96, AMVM97, ACVM97, AM9S80, AC9S80, AR9S80, AD9S80, AR9T96, AD9T96 (seven-segment display controls)

Likely causes, most common first

  1. Blown fuse or tripped circuit breaker
  2. Manual disconnect switch turned OFF, door switch open or 24 volt wire improperly connected or loose
  3. Furnace electrical supply shared with other devices
  4. Integrated control module is non-functional

What you can safely check yourself

  • Check the furnace breaker in the electrical panel and reset it once if it has tripped
  • Check that the service switch on or near the furnace is on
  • Check that the furnace door panel is fully seated - the door switch cuts power when the panel is off

When to call a technician

If the breaker, switch and door panel are fine and there is still no display, the transformer or control board needs a technician.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.