Hard lockout

The control board is not energizing the gas valve when it should be. No gas, no heat.

Manual wording: “Integrated Control Board is not energizing the gas valve when it should be on.

Documented for: Amana AMVC96, ACVC96, AMVM97, ACVM97, AM9S80, AC9S80, AR9S80, AD9S80, AR9T96, AD9T96 (seven-segment display controls)

Likely causes, most common first

  1. Miswired gas valve circuit
  2. Open gas valve circuit
  3. Gas valve relay on integrated control board stuck open

When to call a technician

Gas valve circuit diagnosis is technician work. The manual is explicit that the control board, not the gas valve, is the part to replace for this code.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.