HVAC Code Lookup

Amana Furnace Code EE9

Warning

High-stage pressure switch never closed, so the furnace will not go to high fire. It usually keeps heating on low stage, which feels underpowered in cold weather.

Manual wording: “High-stage pressure switch circuit open.

Documented for: Amana AMVC96, ACVC96, AMVM97, ACVM97, AM9S80, AC9S80, AR9S80, AD9S80, AR9T96, AD9T96 (seven-segment display controls)

Likely causes, most common first

  1. Pressure switch hose blocked, pinched, or connected improperly
  2. Blocked flue pipe and/or inlet air pipe, blocked drain system or weak induced draft blower
  3. Incorrect pressure switch set point or malfunctioning switch contacts
  4. Loose or improperly connected wiring

What you can safely check yourself

  • Check the outdoor intake and exhaust pipes for snow, ice or debris
  • Check the condensate drain line and trap for a clog

When to call a technician

If the venting and drain are clear, the high-stage pressure switch and inducer need a technician.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.