HVAC Code Lookup

Amana Furnace Code EE1

Soft lockout

Low-stage pressure switch was already closed when the heat cycle started, so the control will not light the burners.

Manual wording: “Low-stage pressure switch circuit closed at start of heating cycle.

Documented for: Amana AMVC96, ACVC96, AMVM97, ACVM97, AM9S80, AC9S80, AR9S80, AD9S80, AR9T96, AD9T96 (seven-segment display controls)

Likely causes, most common first

  1. Low stage pressure switch contacts sticking
  2. Short in pressure switch circuit wiring

What you can safely check yourself

  • Turn the furnace off at its power switch for 30 seconds and back on once

When to call a technician

A stuck pressure switch is a safety-proving device and must be replaced by a technician, never jumpered.

A Amana furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Amana codes